That's it! It's coming back to me now. This is affecting only Canopy APs
with sync over power going into a CTM2.

What would be the best wiring or pin out method in this case?

On Tuesday, April 21, 2015, Chuck McCown <ch...@wbmfg.com> wrote:

>   LMG discovered this about 10 years ago or whenever their first sync
> product came out.  The fix was the balanced sync over power wiring schema.
>
>  *From:* Ken Hohhof <javascript:_e(%7B%7D,'cvml','af...@kwisp.com');>
> *Sent:* Tuesday, April 21, 2015 1:24 PM
> *To:* af@afmug.com <javascript:_e(%7B%7D,'cvml','af@afmug.com');>
> *Subject:* Re: [AFMUG] CAT5 crosstalk on tower legs
>
>   The thread about Cat5 ziptied to tower legs probably involved sync over
> power and surge protectors.
>
>  *From:* Josh Luthman
> <javascript:_e(%7B%7D,'cvml','j...@imaginenetworksllc.com');>
> *Sent:* Tuesday, April 21, 2015 2:12 PM
> *To:* af@afmug.com <javascript:_e(%7B%7D,'cvml','af@afmug.com');>
> *Subject:* Re: [AFMUG] CAT5 crosstalk on tower legs
>
>  Damn near every tall tower I've done straight up the legs and zip tied
> right onto the legs.
>
> Grab shielded cabling and do it again, I bet you have water in the line.
> Double check your connectors at the bottom for corrosion or water.
>
>
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
> On Tue, Apr 21, 2015 at 3:05 PM, Eric Muehleisen <ericm...@gmail.com
> <javascript:_e(%7B%7D,'cvml','ericm...@gmail.com');>> wrote:
>
>> A while back there was a thread about issues running CAT5 cables along
>> the entire length of solid steel tower legs.
>>
>> We've run into a problem where we can't run 100baseT reliably on a couple
>> APs. CRC errors will go away if we force the switch port to 10baseT.
>> Interestingly enough, packet loss amplifies when it rains.
>>
>> Any help would be appreciated.
>>
>>
>> --
>> Sent via mobile
>>
>
>


-- 
Sent via mobile

Reply via email to