That's it! It's coming back to me now. This is affecting only Canopy APs with sync over power going into a CTM2.
What would be the best wiring or pin out method in this case? On Tuesday, April 21, 2015, Chuck McCown <ch...@wbmfg.com> wrote: > LMG discovered this about 10 years ago or whenever their first sync > product came out. The fix was the balanced sync over power wiring schema. > > *From:* Ken Hohhof <javascript:_e(%7B%7D,'cvml','af...@kwisp.com');> > *Sent:* Tuesday, April 21, 2015 1:24 PM > *To:* af@afmug.com <javascript:_e(%7B%7D,'cvml','af@afmug.com');> > *Subject:* Re: [AFMUG] CAT5 crosstalk on tower legs > > The thread about Cat5 ziptied to tower legs probably involved sync over > power and surge protectors. > > *From:* Josh Luthman > <javascript:_e(%7B%7D,'cvml','j...@imaginenetworksllc.com');> > *Sent:* Tuesday, April 21, 2015 2:12 PM > *To:* af@afmug.com <javascript:_e(%7B%7D,'cvml','af@afmug.com');> > *Subject:* Re: [AFMUG] CAT5 crosstalk on tower legs > > Damn near every tall tower I've done straight up the legs and zip tied > right onto the legs. > > Grab shielded cabling and do it again, I bet you have water in the line. > Double check your connectors at the bottom for corrosion or water. > > > Josh Luthman > Office: 937-552-2340 > Direct: 937-552-2343 > 1100 Wayne St > Suite 1337 > Troy, OH 45373 > > On Tue, Apr 21, 2015 at 3:05 PM, Eric Muehleisen <ericm...@gmail.com > <javascript:_e(%7B%7D,'cvml','ericm...@gmail.com');>> wrote: > >> A while back there was a thread about issues running CAT5 cables along >> the entire length of solid steel tower legs. >> >> We've run into a problem where we can't run 100baseT reliably on a couple >> APs. CRC errors will go away if we force the switch port to 10baseT. >> Interestingly enough, packet loss amplifies when it rains. >> >> Any help would be appreciated. >> >> >> -- >> Sent via mobile >> > > -- Sent via mobile