Tushar, when you say ground block you mean a surge suppressor? On Sunday, October 25, 2015, Tushar Patel <tpa...@ecpi.com> wrote:
> We used to loose lot of radios too. > > We do following now and it seems to help (loosing less). > > At top on the tower: > We put all AP on stand off (MTOW-p), then we have grounding block mounted > on the stand off at same level as AP, then less then 2 feet of cable going > from grounding block to AP. All shielded cable and grounded to tower. > > We have lost few ground block on tower but it seems to save radios. > > Some ideas came from orthogone system product and their grounding guide > lines. > > At the bottom > > Shielded cable going to grounding block and then to equipments. > > Tushar > > > > On Oct 25, 2015, at 10:57 AM, Gino Villarini <ginovi...@gmail.com > <javascript:;>> wrote: > > > > So we are loosing radios left and right due to lightning! > > > > Typical site setup: > > > > Radios on tower grounded to tower > > > > Shielded cable > > > > Shielded patch panel - grounded > > > > Regular cat5 jumpers > > > > Wbmfg SS - grounded > > > > Regular cat5 jumpers > > > > Poe device > > > > What's wrong? > > > > >