Tushar, when you say ground block you mean a surge suppressor?

On Sunday, October 25, 2015, Tushar Patel <tpa...@ecpi.com> wrote:

> We used to loose lot of radios too.
>
> We do following now and it seems to help (loosing less).
>
> At top on the tower:
> We put all AP on stand off (MTOW-p), then we have grounding block mounted
> on the stand off at same level as AP, then less then 2 feet of cable going
> from grounding block to AP. All shielded cable and grounded to tower.
>
> We have lost few ground block on tower but it seems to save radios.
>
> Some ideas came from orthogone system product and their grounding guide
> lines.
>
> At the bottom
>
> Shielded cable going to grounding block and then to equipments.
>
> Tushar
>
>
> > On Oct 25, 2015, at 10:57 AM, Gino Villarini <ginovi...@gmail.com
> <javascript:;>> wrote:
> >
> > So we are loosing radios left and right due to lightning!
> >
> > Typical site setup:
> >
> > Radios on tower grounded to tower
> >
> > Shielded cable
> >
> > Shielded patch panel - grounded
> >
> > Regular cat5 jumpers
> >
> > Wbmfg SS - grounded
> >
> > Regular cat5 jumpers
> >
> > Poe device
> >
> > What's wrong?
> >
> >
>

Reply via email to