One thing we've been doing for several years now is a bonding wire up the tower. I do not trust the tower steel/leg joints being low enough resistance. Failure rate went way down. DC and fuses doesn't hurt either.

On 10/25/2015 10:57 AM, Gino Villarini wrote:
So we are loosing radios left and right due to lightning!

Typical site setup:

Radios on tower grounded to tower

Shielded cable

Shielded patch panel - grounded

Regular cat5 jumpers

Wbmfg SS - grounded

Regular cat5 jumpers

Poe device

What's wrong?