Yes

On Sunday, October 25, 2015, Josh Luthman <j...@imaginenetworksllc.com>
wrote:

> Shielded cable to the SS for sure...
>
> Have you looked at doing fiber/DC up the tower and then distribute it out
> that way?
>
>
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
> On Sun, Oct 25, 2015 at 11:57 AM, Gino Villarini <ginovi...@gmail.com
> <javascript:_e(%7B%7D,'cvml','ginovi...@gmail.com');>> wrote:
>
>> So we are loosing radios left and right due to lightning!
>>
>> Typical site setup:
>>
>> Radios on tower grounded to tower
>>
>> Shielded cable
>>
>> Shielded patch panel - grounded
>>
>> Regular cat5 jumpers
>>
>> Wbmfg SS - grounded
>>
>> Regular cat5 jumpers
>>
>> Poe device
>>
>> What's wrong?
>>
>>
>>
>