Thanks Josh, I was not sure if I could just put 48 volts to the unit powering the 450i or not.
Best regards, Brandon Yuchasz GogebicRange.net www.gogebicrange.net <http://www.gogebicrange.net/> From: Af [mailto:[email protected]] On Behalf Of Josh Luthman Sent: Monday, November 30, 2015 3:42 PM To: [email protected] Subject: Re: [AFMUG] syncinjector for 450i and FSK100 http://store.packetflux.com/gigabit-syncinjector-for-24-volt-cambium-radios/ http://store.packetflux.com/syncpipe-basic/ Plus a 24v and a 48v power supply (450i is 48v, fsk is 24v). Yes you can daisy chain from the syncpipe, to the syncinjector and so on Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Mon, Nov 30, 2015 at 4:37 PM, Brandon Yuchasz <[email protected]> wrote: Just to be clear can anyone tell me what version of syncinjector I need to run a pmp450i? Is there a version that can run both a 450i and pmp100 AP? If not can I daisy chain the GPS sync from the first syncinjector running the 450i to the syncinjector running the older pmp100 aps? Best regards, Brandon Yuchasz GogebicRange.net www.gogebicrange.net <http://www.gogebicrange.net/>