You can.  It will take up to 57v.

And once again I'll yell at Forrest to correct that posting.


Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Mon, Nov 30, 2015 at 4:51 PM, Brandon Yuchasz <[email protected]>
wrote:

> Thanks Josh,
>
> I was not sure if I could just put 48 volts to the unit powering the 450i
> or not.
>
>
>
> Best regards,
>
> Brandon Yuchasz
>
> GogebicRange.net
>
> www.gogebicrange.net
>
>
>
> *From:* Af [mailto:[email protected]] *On Behalf Of *Josh Luthman
> *Sent:* Monday, November 30, 2015 3:42 PM
> *To:* [email protected]
> *Subject:* Re: [AFMUG] syncinjector for 450i and FSK100
>
>
>
>
> http://store.packetflux.com/gigabit-syncinjector-for-24-volt-cambium-radios/
>
> http://store.packetflux.com/syncpipe-basic/
>
> Plus a 24v and a 48v power supply (450i is 48v, fsk is 24v).
>
>
>
> Yes you can daisy chain from the syncpipe, to the syncinjector and so on
>
>
>
>
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
>
>
> On Mon, Nov 30, 2015 at 4:37 PM, Brandon Yuchasz <[email protected]>
> wrote:
>
> Just to be clear can anyone tell me what version of syncinjector I need to
> run a pmp450i? Is there a version that can run both a 450i and pmp100 AP?
> If not can I daisy chain the GPS sync from the first syncinjector running
> the 450i to the syncinjector running the older pmp100 aps?
>
>
>
>
>
> Best regards,
>
> Brandon Yuchasz
>
> GogebicRange.net
>
> www.gogebicrange.net
>
>
>
>
>

Reply via email to