Steve,

It is a high impedance input and will accept any voltage from 3 to 12V,
and any frequency from 44.1 to 96KHz. The output impedance of the clock
source is not important - your 50 ohm drive is fine.

When in word clock mode, Transporter is agnostic of the input sample
rate, and will play at whatever rate it is fed.

If the Pace-Car automatically outputs the correct frequency based on
the incoming s/pdif signalling bits, then everything should just work.
However, there will necessarily be a brief drop in the signal when
switching from one frequency to another, while the PLL re-synchs.

Can you describe the problem you're having?