Steve, It is a high impedance input and will accept any voltage from 3 to 12V, and any frequency from 44.1 to 96KHz. The output impedance of the clock source is not important - your 50 ohm drive is fine.
When in word clock mode, Transporter is agnostic of the input sample rate, and will play at whatever rate it is fed. If the Pace-Car automatically outputs the correct frequency based on the incoming s/pdif signalling bits, then everything should just work. However, there will necessarily be a brief drop in the signal when switching from one frequency to another, while the PLL re-synchs. Can you describe the problem you're having? Sean -- seanadams ------------------------------------------------------------------------ seanadams's Profile: http://forums.slimdevices.com/member.php?userid=3 View this thread: http://forums.slimdevices.com/showthread.php?t=50273 _______________________________________________ audiophiles mailing list audiophiles@lists.slimdevices.com http://lists.slimdevices.com/lists/listinfo/audiophiles