I'm having difficulty posting so I apologize if this is a repost.
 
 
 
 
Hello Everyone,
 
            I’m new to using Bacula and am having a little trouble setting up 
the configurations.
 
 
When I run cat /proc/scsi/scsi I get the following back
 
Attached devices:
Host: scsi0 Channel: 00 Id: 00 Lun: 00
  Vendor: DELL     Model: PV-132T          Rev: 308D
  Type:   Medium Changer                   ANSI SCSI revision: 02
Host: scsi0 Channel: 00 Id: 01 Lun: 00
  Vendor: IBM      Model: ULTRIUM-TD2      Rev: 53Y3
  Type:   Sequential-Access                ANSI SCSI revision: 03
Host: scsi0 Channel: 01 Id: 02 Lun: 00
  Vendor: IBM      Model: ULTRIUM-TD2      Rev: 37RH
  Type:   Sequential-Access                ANSI SCSI revision: 03
Host: scsi1 Channel: 00 Id: 08 Lun: 00
  Vendor: DP       Model: BACKPLANE        Rev: 1.05
  Type:   Enclosure                        ANSI SCSI revision: 05
Host: scsi1 Channel: 02 Id: 00 Lun: 00
  Vendor: DELL     Model: PERC 5/i         Rev: 1.03
  Type:   Direct-Access                    ANSI SCSI revision: 05
 
Next I run mtx –f /dev/sg0 status
 
  Storage Changer /dev/sg0:2 Drives, 23 Slots ( 1 Import/Export )
Data Transfer Element 0:Empty
Data Transfer Element 1:Empty
      Storage Element 1:Full :VolumeTag=000013                          
      Storage Element 2:Full :VolumeTag=000019                          
      Storage Element 3:Full :VolumeTag=000020                          
      Storage Element 4:Full :VolumeTag=000021                          
      Storage Element 5:Full :VolumeTag=000017                          
      Storage Element 6:Full :VolumeTag=000018                          
      Storage Element 7:Full :VolumeTag=000022                          
      Storage Element 8:Full :VolumeTag=000001                          
      Storage Element 9:Full :VolumeTag=000008                          
      Storage Element 10:Full :VolumeTag=000004                          
      Storage Element 11:Full :VolumeTag=000007                          
      Storage Element 12:Full :VolumeTag=000011                          
      Storage Element 13:Full :VolumeTag=000009                          
      Storage Element 14:Full :VolumeTag=000010                          
      Storage Element 15:Full :VolumeTag=000016                          
      Storage Element 16:Full :VolumeTag=000002                          
      Storage Element 17:Empty:VolumeTag=                                
      Storage Element 18:Full :VolumeTag=000014                          
      Storage Element 19:Full :VolumeTag=000015                          
      Storage Element 20:Full :VolumeTag=000003                          
      Storage Element 21:Full :VolumeTag=000005                          
      Storage Element 22:Full :VolumeTag=000006                          
      Storage Element 23 IMPORT/EXPORT:Full :VolumeTag=000012  
 
/mtx –f /dev/sg0 inquiry shows:
 
Product Type: Medium Changer
Vendor ID: 'DELL    '
Product ID: 'PV-132T         '
Revision: '308D'
Attached Changer API: No
 
/mtx –f /dev/sg1 inquiry shows:
Product Type: Tape Drive
Vendor ID: 'IBM     '
Product ID: 'ULTRIUM-TD2     '
Revision: '53Y3'
Attached Changer API: No
 
/mtx –f /dev/sg2 inquiry shows:
Product Type: Tape Drive
Vendor ID: 'IBM     '
Product ID: 'ULTRIUM-TD2     '
Revision: '37RH'
Attached Changer API: No
 
/mt –f /dev/nst0 status shows:
SCSI 2 tape drive:
File number=-1, block number=-1, partition=0.
Tape block size 0 bytes. Density code 0x0 (default).
Soft error count since last status=0
General status bits on (50000):
 DR_OPEN IM_REP_EN
 
 
 
In bacula-sd.conf I have the following setup:
 
Autochanger {
  Name = Autochanger
  Device = DellPowerVault132T
  Changer Command = "/etc/bacula/mtx-changer %c %o %S %a %d"
  Changer Device = /dev/sg0
}
 
Device {
  Name = DellPowerVault132T
  LabelMedia = yes
  Drive Index = 0
  Media Type = LTO-3
  Archive Device = /dev/nst0
  AutomaticMount = yes;
  AlwaysOpen = yes;
  RemovableMedia = yes;
RandomAccess = no;
AutoChanger = yes
Hardware End of Medium = No
BSF at EOM = yes
# Enable the Alert command only if you have the mtx package loaded 
Alert Command = "sh -c 'tapeinfo -f %c |grep TapeAlert|cat'"
TWO EOF = yes
}
 
 
Also in the bacula-dir.conf I have the following setup:
Storage {
  Name = File
# Do not use "localhost" here    
  Address = <<server_name>>                # N.B. Use a fully qualified name 
here
  SDPort = 9103
  Password = "<xxx>"
  Device = DellPowerVault132T
  Media Type = LTO-3
}
 
 
Does everything look correctly setup? 
 
When I try to mounting the storage using the Webmin Bacula console I get the 
following error:
 
Mounting volume on storage device File .. Automatically selected Catalog: 
MyCatalogUsing Catalog "MyCatalog"3301 Issuing autochanger "loaded? drive 0" 
command.3302 Autochanger "loaded? drive 0", result: nothing loaded.3901 open 
device failed: ERR=dev.c:433 Unable to open device "DellPowerVault132T" 
(/dev/nst0): ERR=No medium found 
 
 
Any help would be appreciated.
 
Thanks,
Nick
_________________________________________________________________
Watch “Cause Effect,” a show about real people making a real difference.
http://im.live.com/Messenger/IM/MTV/?source=text_watchcause
-------------------------------------------------------------------------
Check out the new SourceForge.net Marketplace.
It's the best place to buy or sell services for
just about anything Open Source.
http://ad.doubleclick.net/clk;164216239;13503038;w?http://sf.net/marketplace
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to