I wonder your register settings might be wrong.. What you get if you do .

 

Swtich# sh version

 

Regards,

Masood Ahmad Shah

 

 

From: Ali Aydemir [mailto:[EMAIL PROTECTED] 
Sent: Thursday, February 21, 2008 4:55 PM
To: Masood Ahmad Shah
Cc: [email protected]
Subject: Re: [OSL | CCIE_RS] boot problem on 4948 SW

 


Thanks your advise but  "no boot manual"  not in usuable command list

DataCentre_2(config)#no boot ?
  bootldr    Boot loader (RxBoot) image name
  bootstrap  Bootstrap image file
  host       Router-specific config file
  network    Network-wide config file
  system     System image file

DataCentre_2(config)#


and i use 

DataCentre_2(config)#boot system flash cat4000-i9s-mz.122-25.EWA7.bin

but same propblem. Switch is boot on rommon..

if that is any mean



****************************************************************************
************************************************************************
rommon 2 >?
 alias              set and display aliases command
 boot               boot up an external process
 clear              clear configurations, use 'clear help' for more info
 confreg            configuration register utility
 dev                list the device table with physical device information
 dir                list filesystem information
 help               monitor builtin command help
 history            monitor command history
 macstats           print management port MAC statistics counters
 meminfo            main memory information
 ping               ping utility to determine network connectivity
 repeat             repeat a monitor command
 reset              system reset
 set                show/set environment vars, use 'set help' for more info
 sprom              serial eprom operations
 sysret             print out info from last system return
 unalias            unset an alias
 unset              unset a monitor variable
 version            display Rom Monitor version information
rommon 3 >boot

Rommon reg: 0xE2004180
##########
k2diags version 4.2.2_h

prod: WS-C4948  part: 73-9130-08  serial: FOX10450KV2


Power-on-self-test for Module 1:  WS-C4948
 Port/Test Status: (. = Pass, F = Fail, U = Untested)



Port Traffic: L2 Asic Loopback ...
 0: .  1: .  2: .  3: .  4: .  5: .  6: .  7: .  8: .  9: . 10: . 11: . 
12: . 13: . 14: . 15: . 16: . 17: . 18: . 19: . 20: . 21: . 22: . 23: . 
24: . 25: . 26: . 27: . 28: . 29: . 30: . 31: . 32: . 33: . 34: . 35: . 
36: . 37: . 38: . 39: . 40: . 41: . 42: . 43: . 44: . 45: . 46: . 47: . 


Port Traffic: L3 Asic Loopback ...
 0: .  1: .  2: .  3: .  4: .  5: .  6: .  7: .  8: .  9: . 10: . 11: . 
12: . 13: . 14: . 15: . 16: . 17: . 18: . 19: . 20: . 21: . 22: . 23: . 
24: . 25: . 26: . 27: . 28: . 29: . 30: . 31: . 32: . 33: . 34: . 35: . 
36: . 37: . 38: . 39: . 40: . 41: . 42: . 43: . 44: . 45: . 46: . 47: . 


Switch Subsystem Memory ...
 1: .  2: .  3: .  4: .  5: .  6: .  7: .  8: .  9: . 10: . 11: . 12: . 
13: . 14: . 15: . 16: . 17: . 18: . 19: . 20: . 21: . 22: . 23: . 24: . 
25: . 26: . 27: . 28: . 29: . 30: . 31: . 32: . 33: . 34: . 35: . 36: . 
37: . 38: . 39: . 40: . 41: . 42: . 43: . 44: . 45: . 46: . 47: . 48: . 
49: . 50: . 51: . 52: . 53: . 54: . 55: . 


Front Panel Ports ...
 1: .  2: .  3: .  4: .  5: .  6: .  7: .  8: .  9: . 10: . 11: . 12: . 
13: . 14: . 15: . 16: . 17: . 18: . 19: . 20: . 21: . 22: . 23: . 24: . 
25: . 26: . 27: . 28: . 29: . 30: . 31: . 32: . 33: . 34: . 35: . 36: . 
37: . 38: . 39: . 40: . 41: . 42: . 43: . 44: . 45: . 46: . 47: . 48: . 


Module 1 Passed


Exiting to ios...

Rommon reg: 0xE2000180
###################################
              Restricted Rights Legend

Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.

           cisco Systems, Inc.
           170 West Tasman Drive
           San Jose, California 95134-1706



Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9S-M),
Version 12.2(25)EWA7, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2006 by Cisco Systems, Inc.
Compiled Mon 16-Oct-06 18:23 by dchih
Image text-base: 0x10000000, data-base: 0x114EEE78

cisco WS-C4948 (MPC8245) processor (revision 0) with 262144K bytes of
memory.
Processor board ID FOX10450KV2
MPC8245 CPU at 266Mhz, Fixed Module
Last reset from Reload
1 Virtual Ethernet interface
48 Gigabit Ethernet interfaces
511K bytes of non-volatile configuration memory.

Uncompressed configuration from 1893 bytes to 5178 bytes


Press RETURN to get started!


00:00:15: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
00:00:17: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 1 (WS-C4948 S/N:
FOX10450KV2 Hw: 1.4) is online
000003: 00:00:17: %SYS-6-CLOCKUPDATE: System clock has been updated from
03:27:40 UTC Thu Feb 21 2008 to 05:27:40 UTC Thu Feb 21 2008, configured
from console by console.
000004: 00:00:17: %SYS-6-CLOCKUPDATE: System clock has been updated from
05:27:40 UTC Thu Feb 21 2008 to 05:27:40 UTC Thu Feb 21 2008, configured
from console by console.
000005: 00:00:17: %SYS-5-CONFIG_I: Configured from memory by console
000006: 00:00:18: %SYS-5-RESTART: System restarted --
Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9S-M),
Version 12.2(25)EWA7, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2006 by Cisco Systems, Inc.
Compiled Mon 16-Oct-06 18:23 by dchih
DataCentre_2>en
DataCentre_2>enable 
DataCentre_2#
****************************************************************************
************************************************************************



thanks.







2008/2/21, Masood Ahmad Shah <[EMAIL PROTECTED]>:

You may need to check boot variable. 

 

This might solve your problem...    

 

Jahil-1(config)# no boot manual

 

Regards,

Masood Ahmad Shah

 

 

From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Ali Aydemir
Sent: Thursday, February 21, 2008 1:06 PM
To: [email protected]
Subject: [OSL | CCIE_RS] boot problem on 4948 SW

 


That switch boot on rommon every startup.. we dont understand why.

Thanks for suggestions.



****************************************************************************
****************************************************************************
****************


DataCentre_1#sh version 
Cisco IOS Software, Catalyst 4000 L3 Switch Software (cat4000-I9S-M),
Version 12.2(25)EWA7, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2006 by Cisco Systems, Inc.
Compiled Mon 16-Oct-06 18:23 by dchih
Image text-base: 0x10000000, data-base: 0x114EEE78

ROM: 12.2(20r)EW1
Dagobah Revision 226, Swamp Revision 5

DataCentre_1 uptime is 1 week, 5 days, 8 hours, 42 minutes
System returned to ROM by power-on
System image file is "bootflash:cat4000-i9s-mz.122-25.EWA7.bin"

cisco WS-C4948 (MPC8245) processor (revision 0) with 262144K bytes of
memory.
Processor board ID FOX10450KVG
MPC8245 CPU at 266Mhz, Fixed Module
Last reset from PowerUp
1 Virtual Ethernet interface
48 Gigabit Ethernet interfaces
511K bytes of non-volatile configuration memory.

Configuration register is 0x2102



****************************************************************************
****************************************************************************
****************


DataCentre_1#sh runn
Building configuration...

Current configuration : 5504 bytes
!
version 12.2
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
service compress-config
service sequence-numbers
!
hostname DataCentre_1
!
boot-start-marker
boot-end-marker
!
!
username admin privilege 15 secret 5 $1$9GCt$lq3FGtMluCZMmoU1gQeZE1
no aaa new-model
clock timezone UTC 2
clock summer-time UTC recurring last Sun Mar 3:00 last Sun Oct 4:00
ip subnet-zero
no ip domain-lookup
ip domain-name belbim.local
ip name-server 192.168.100.35
!
!
no file verify auto
spanning-tree mode pvst
spanning-tree extend system-id
power redundancy-mode redundant
!
!
!
vlan internal allocation policy ascending
!
interface GigabitEthernet1/1
 switchport access vlan 3
 switchport mode access
 spanning-tree portfast
!
interface GigabitEthernet1/2
 switchport access vlan 3
 switchport mode access
!
interface GigabitEthernet1/3
 switchport access vlan 23
 switchport mode access
 spanning-tree portfast
!
interface GigabitEthernet1/4
 switchport access vlan 11
 switchport mode access
 spanning-tree portfast
.
.
.
.
.

****************************************************************************
****************************************************************************
****************

 

Reply via email to