I haven't tried this but from the CUC help pages, you should be able to
disable the beep completely by changing the timeout to zero.

The following procedure is optional. It adjusts the interval between beeps
while Cisco Unity Connection is recording a phone conversation.
 To Adjust the Live Record Beep Interval (Optional)
Step 1 In Cisco Unity Connection Administration, expand *System Settings*,
then click *Advanced > Telephony*.

   1. On the Telephony Configuration page, in the Live Record Beep Interval
   in Milliseconds field, enter the interval (in milliseconds) between beeps
   when a phone conversation is being recorded by using the live record
   feature.
   If the setting is blank, the interval is 15,000 milliseconds. If the
   setting is 0, the beep is disabled.
   2. Click *Save*.



On Fri, Nov 25, 2011 at 9:52 PM, Edgar Feliz <ejzi...@gmail.com> wrote:

> If given the task of configuring live-record but part of the requirement
> states that the TONE NOT be played back to the users when recording has
> begun, how is this done? I have looked in CUC and CCM and don't see a way
> to stop this.
>
> E
>