Dear All, Question: Has anybody ever refined the same structure using PHENIX and then tried REFMAC to see what happens?
I did and I stumbled on something funny. I'm refining a structure at 1.1A resolution which was solved with Iodine phasing using PHENIX AutoSolve. Got a great map and the structure was built almost completely. I had to build a few residues myself, and using the published sequence, I started filling in the residues, but as I came nearer the N-terminus, it looked like the density did not match residues from the sequence. I kept the residues as in the sequence, but as you can see from the PHENIX refined picture (below is the link) it still looks like the amino acid sequence in the crystal does not match the published protein sequence. Out of interest I refined the same file in REFMAC, and now the electron density is correct, and the sequence of the amino acids in the crystal matches the published sequence (see link for picture below). Not only that..... my R/Rfree improved (16.5/19 for PHENIX, 10/18 for REFMAC). I've also refined the occupancies of the iodide, however the the output FO-FC map from PHENIX complains and the REFMAC map is fine..... How can this be and what causes this? Link for the pictures: Both maps are at identical Sigma levels in both pictures. PHENIX: http://dl.dropbox.com/u/51868657/PHENIX_refined.png REFMAC: http://dl.dropbox.com/u/51868657/REFMAC_refined.png Cheers, Chris Browning -- Dr. Christopher Browning Post-Doctor to Prof. Petr Leiman EPFL BSP-416 1015 Lausanne Switzerland Tel: 0041 (0) 02 16 93 04 40