Yes it definately could have been learned from the provider or you had
it configured on your router at some point and later took it out of your
config.  It the second case is true a reload will get rid of it.  Does
it claim to be learned dynamically??

  Dave

matt wrote:
> 
> So...I am looking at some frame links that a co-worker
> brought up not long ago.  I issue a "show frame-relay
> pvc" command and notice that there are 3 dlci's being
> seen by the router yet there are only 2 circuits.  The
> 3rd "unknown" dlci is listed as being unused.  So, I
> look through the config some more and confirm that the
> 3rd dlci is not defined anywhere in the config.  I am
> guessing my router is learning this dlci from the
> providers frame switch??  But why?
> 
> Feel free to correct me if I am wrong...and thanks in
> advance for the help.
> 
> matt
> 
> __________________________________________________
> Do You Yahoo!?
> Send FREE video emails in Yahoo! Mail!
> http://promo.yahoo.com/videomail/
-- 
David Madland
Sr. Network Engineer
CCIE# 2016
Qwest Communications Int. Inc.
[EMAIL PROTECTED]
612-664-3367

"Emotion should reflect reason not guide it"




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=31217&t=31210
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]