what's the unused column? -Patrick
>>> "Scott Nawalaniec" 01/07/02 05:10PM >>> Hi Matt, You are correct...The DLCI is being learned from the frame-relay switch...You don't have it configured so it will show up under the unused column when the sho fram pvc command. Did you order the pvc and haven't configured it or assigned it to an interface/sub-interface? Or the provider assigned it to a wrong dlci which I just had happened last week and the week before..... HTH, Scott -----Original Message----- From: matt [mailto:[EMAIL PROTECTED]] Sent: Monday, January 07, 2002 1:53 PM To: [EMAIL PROTECTED] Subject: Frame Relay Question [7:31210] So...I am looking at some frame links that a co-worker brought up not long ago. I issue a "show frame-relay pvc" command and notice that there are 3 dlci's being seen by the router yet there are only 2 circuits. The 3rd "unknown" dlci is listed as being unused. So, I look through the config some more and confirm that the 3rd dlci is not defined anywhere in the config. I am guessing my router is learning this dlci from the providers frame switch?? But why? Feel free to correct me if I am wrong...and thanks in advance for the help. matt __________________________________________________ Do You Yahoo!? Send FREE video emails in Yahoo! Mail! http://promo.yahoo.com/videomail/ Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=31281&t=31210 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]