what's the unused column?

-Patrick

>>> "Scott Nawalaniec"  01/07/02 05:10PM >>>
Hi Matt,

You are correct...The DLCI is being learned from the frame-relay
switch...You don't have it configured so it will show up under the unused
column when the sho fram pvc command. Did you order the pvc and haven't
configured it or assigned it to an interface/sub-interface? Or the provider
assigned it to a wrong dlci which I just had happened last week and the week
before.....

HTH,


Scott

-----Original Message-----
From: matt [mailto:[EMAIL PROTECTED]] 
Sent: Monday, January 07, 2002 1:53 PM
To: [EMAIL PROTECTED] 
Subject: Frame Relay Question [7:31210]


So...I am looking at some frame links that a co-worker
brought up not long ago.  I issue a "show frame-relay
pvc" command and notice that there are 3 dlci's being
seen by the router yet there are only 2 circuits.  The
3rd "unknown" dlci is listed as being unused.  So, I
look through the config some more and confirm that the
3rd dlci is not defined anywhere in the config.  I am
guessing my router is learning this dlci from the
providers frame switch??  But why?

Feel free to correct me if I am wrong...and thanks in
advance for the help.

matt


__________________________________________________
Do You Yahoo!?
Send FREE video emails in Yahoo! Mail!
http://promo.yahoo.com/videomail/