Thanks guys. Tried the TERA TERM program and it works. Why do I even use HyperTerm?
""Georg Pauwen"" wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECTED]... > Hi Kevin, > > this is from the Cisco site: > > Console Port Problem on Cisco 2500 > > Symptom > Output from the router on the console screen can be seen, but anything which > is typed in is not seen. > > Problem > The terminal is set to use Ready To Send/Clear To Send (RTS/CTS) flow > control. > > On all other routers, the console port is wired to connect RTS and CTS so > even though we don't do real flow control, the terminal sees CTS in response > to asserting RTS. > > Due to the RJ45 -> DB25 adapter wiring for the 2500, this is not possible. > > Solution > Disable hardware flowcontrol or strap CTS high. > > Hope this helps, > > Georg Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=41150&t=40966 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]