Sorry for the lack of response until now; I'm on a mid-shift. I was able to
get more info on this here (apparently it was a known issue, but not made
known to me), and the problem is exactly as everyone has suggested: The
circuit routes through TouchAmerica's network, and they have the PVC mapped
wrong. Thanks for your responses!
GM

-----Original Message-----
From: Mossburg, Geoff (MAN-Corporate) 
Sent: Tuesday, January 07, 2003 11:20 PM
To: [EMAIL PROTECTED]
Subject: frame relay stumper [7:60567]


How's this for nutty: We have a frame-relay point-to-point circuit going
between our Cisco 7500 core router and a 2500 remote router, and the
subinterfaces have IP addys of .1 and .2, respectively. Both sides'
subinterfaces are "up/up", but I am not able to ping either IP address, even
when I am on the host router for each address! Both sides have other working
subinterfaces which I have tested similarly, and these use the same physical
circuit, so I know the circuit is good. OH... and this connection WAS
working at some point, but I can't tell when it stopped working, due to the
fact that neither router recognizes that there is a problem. I tried
bouncing both subinterfaces and reloading the 2500, but the problem remains.
Any advice about what I may be overlooking would be a Godsend.
Thanks!
GM




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=60642&t=60567
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to