Essentially impossible on my K3S. I could never get my head around HRD (even
when it was free) so I can't speak to that. But with MMTTY I have my Windows
slider at 20% and the Mic/Line Level control is still so sensitive that a change
from 6 to 7 takes the ALC from 3 to 5 bars. These low setting then require an
increase in VOX gain that then makes it too sensitive on SSB. Lowering the
Windows gain exacerbates the problem. VOX and Mic gains should be totally
independent. Sadly, in the K3 (both vintages) they are not.
If I had the appropriate serial cable I would go back to serial control and Line
In/Line Out.
Wes N7WS
On 9/1/2015 6:58 AM, Don Wilhelm wrote:
Adjust the slider on the computer soundcard control to about 2/3 of full and
then adjust the K3S Line In (Mic gain used in DATA mode) to produce 4 bars
solid with the 5th bar flickering on the ALC meter - you can do that in TX
TEST mode so no RF is transmitted.
73,
Don W3FPR