On page 34 of the Installation and Opeation manual it says to remove the W4 jumber soldered between two pads located between J64A and the KIO3 board. My K3 RF board is Rev A. W4 is hard wired between two pads located between J64A and the KBPF3 board mounted above the K3 RF board. It looks as if I am going to have to temporarily remove the KBPF3 board to remove this jumper. Am I missing something here? Roy Morris W4WFB _______________________________________________ Elecraft mailing list Post to: Elecraft@mailman.qth.net You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com