2014-10-03 0:29 GMT+03:00 Dave Cole <[email protected]>: > I'm using M64 P0 to turn on the waterjet and M65 P0 to turn it off.
Any particular reason not to use M3/M5 commands? At least I did that on my waterjet, customer never commented about that. It just seems like common sense - tool on and tool off, whatever is the tool - spindle, jet of water, electric arc in plasma. Anyway, inserting those G41.1/G42.1, when jet-on and G40 on jet-off moments seems like the easiest way. Viesturs ------------------------------------------------------------------------------ Meet PCI DSS 3.0 Compliance Requirements with EventLog Analyzer Achieve PCI DSS 3.0 Compliant Status with Out-of-the-box PCI DSS Reports Are you Audit-Ready for PCI DSS 3.0 Compliance? Download White paper Comply to PCI DSS 3.0 Requirement 10 and 11.5 with EventLog Analyzer http://pubads.g.doubleclick.net/gampad/clk?id=154622311&iu=/4140/ostg.clktrk _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers