I just reviewed my copy of EN 61000-4-3 and can see where it replaces ENV
50140 but no mention of ENV 50204.  What am I missing?
Dan Kinney
Horner APG

> -----Original Message-----
> From: Gert Gremmen [SMTP:cet...@cetest.nl]
> Sent: Wednesday, September 06, 2000 1:54 PM
> To:   Helge Knudsen; emc-p...@majordomo.ieee.org; wo...@sensormatic.com
> Subject:      RE: Vedr.: ENV 50204
> 
> 
> Hello Helge, Richard and Group,
> 
> Any ENV is a temporary (pre) standard that immediately gets
> withdrawn on the publication date of the replacement standard :
> in this case the publication date of EN 61000-4-3.
> 
> It's existence is justified by the immediate need for a standard, where
> no suitable document is available.
> This of course is independent of the publication of any A1 documents !
> 
> Conclusion:  ENV 50204 is not applicable anymore.
> Regards,
> 
> Gert Gremmen, (Ing)
> 
> ce-test, qualified testing
> 
> ===============================================
> Web presence  http://www.cetest.nl
> CE-shop http://www.cetest.nl/ce_shop.htm
> /-/ Compliance testing is our core business /-/
> ===============================================
> 
> 
> >>-----Original Message-----
> >>From: owner-emc-p...@ieee.org [mailto:owner-emc-p...@ieee.org]On Behalf
> >>Of Helge Knudsen
> >>Sent: Wednesday, September 06, 2000 3:46 PM
> >>To: emc-p...@majordomo.ieee.org; wo...@sensormatic.com
> >>Subject: Vedr.: ENV 50204
> >>
> >>
> >>
> >>Hi Richard and Group,
> >>IEC/EN 61000-4-3/A1 is dealing with "Radiated electromagnetic
> >>field from digital radio telephones", but ENV 50204 is not
> >>withdrawn yet. I beleive this will happen on dow for EN
> >>61000-4-3/A1: 2001-05-01.
> >>Regards
> >>Helge Knudsen
> >>EMC Engineer
> >>Jyske EMC
> >>Literbuen 16B
> >>DK 2740 Skovlunde
> >>Denmark
> >>
> >>>>> <wo...@sensormatic.com> 05-09-00 20:20 >>>
> >>
> >>The Generic Immunity standard, EN 50082-1 references ENV 50204 for a
> >>radiated immunity test. The foreword of  the ENV says it will be
> withdrawn
> >>once an IEC/CENELEC standard has been published. Has this interim
> standard
> >>been withdrawn and replaced by an EN 61000-4 series standard? If so,
> which
> >>one?
> >>
> >>Richard Woods
> >>
> >>-------------------------------------------
> >>This message is from the IEEE EMC Society Product Safety
> >>Technical Committee emc-pstc discussion list.
> >>
> >>To cancel your subscription, send mail to:
> >>     majord...@ieee.org
> >>with the single line:
> >>     unsubscribe emc-pstc
> >>
> >>For help, send mail to the list administrators:
> >>     Jim Bacher:              jim_bac...@mail.monarch.com
> >>     Michael Garretson:        pstc_ad...@garretson.org
> >>
> >>For policy questions, send mail to:
> >>     Richard Nute:           ri...@ieee.org
> >>
> >>
> >>
> >>
> >>-------------------------------------------
> >>This message is from the IEEE EMC Society Product Safety
> >>Technical Committee emc-pstc discussion list.
> >>
> >>To cancel your subscription, send mail to:
> >>     majord...@ieee.org
> >>with the single line:
> >>     unsubscribe emc-pstc
> >>
> >>For help, send mail to the list administrators:
> >>     Jim Bacher:              jim_bac...@mail.monarch.com
> >>     Michael Garretson:        pstc_ad...@garretson.org
> >>
> >>For policy questions, send mail to:
> >>     Richard Nute:           ri...@ieee.org
> >>
> >> << File: Gert Gremmen.vcf >> 

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Jim Bacher:              jim_bac...@mail.monarch.com
     Michael Garretson:        pstc_ad...@garretson.org

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org

Reply via email to