Dear members, >From IEC61000-4-2 and several EN-product standards, they specify the time between successive discharges to be at least 1 second.
But what is the maximum time between each pulse ? I can not see that it is stated in any standards. I guess the test labs use 1 pulse pr second. I feel that the pulse rate can have influences on the EUT performance, so 1 second compared to 3-5 seconds might be the difference between PASS and FAIL. Any suggestions ? Best regards Amund Westin Oslo, Norway -- Get your firstname@lastname email for FREE at http://Nameplanet.com/?su ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Michael Garretson: pstc_ad...@garretson.org Dave Heald davehe...@mediaone.net For policy questions, send mail to: Richard Nute: ri...@ieee.org Jim Bacher: j.bac...@ieee.org All emc-pstc postings are archived and searchable on the web at: http://www.rcic.com/ click on "Virtual Conference Hall,"