Hi all,

I have seen PCB designs with two triangular shaped copper pads pointed
towards each other at very close proximity, meant as an air gap discharge
path for transients. Does anyone have information about such designs,
whether they work and how well ? At a breakdown voltage for air of 1
Megavolt per meter, they should theoretically work: 10mil distance would
have a breakdown voltage of only 254V. Such a PCB design basically comes for
free, so I was thinking of adding it on top of my already existing series
impedance - TVS network. 
Thanks in advance for your comments.

Best regards,
Gabi Hoffknecht

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              emc-p...@hypercom.com
     Dave Heald:               davehe...@mediaone.net

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org
     Jim Bacher:             j.bac...@ieee.org

All emc-pstc postings are archived and searchable on the web at:
    http://ieeepstc.mindcruiser.com/
    Click on "browse" and then "emc-pstc mailing list"

Reply via email to