[EMAIL PROTECTED] wrote:
> hi
> i input with MDI g10 l2 x1 y1 z1
> and Error came Pvalue out of rangewith g10 l2
> Whay is that?
> where is problem?
>   
You must specify a P word to select WHICH coordinate system you are 
setting.  Check docs to see which coord system is set by each P word.
P1 = G54, P2=G55, etc.