rng3 wrote:
> When working with a typical 2 - 3 hp mill and our main goal is to reduce 
> noise that might effect our limit switches, encoders etc. with a 3 phase VFD 
> installation where would we start, line reactor, filter, or both. Any 
> recommend sources? Success stories?
>   
Depends on where the problem is really coming from.  The first thing to 
do is provide a heavy ground conductor to the machine frame.  Make sure 
nothing else is grounded to the machine frame, such as at limit 
switches, encoders, etc. if possible.

Jon

------------------------------------------------------------------------------