On 9 August 2011 04:44, charles green <xxzzb...@yahoo.com> wrote: > the exact message is, "Can't issue MDI command when not homed." AXIS > EMC2.4.6 on Ubuntu 8.04. the homing sequence is axis2=0, axis0=1, axis1=2. > axis3 is not included in the home sequence and has no pins assigned to homing > switch in the hal ini. the configuration is a mill xyza millimeter.
That sounds like an error in that particular config. Axis3 should have a HOME_SEQUENCE but zero HOME_VELOCITY, I think. I will try to experiment when I get home tonight. -- atp "Torque wrenches are for the obedience of fools and the guidance of wise men" ------------------------------------------------------------------------------ uberSVN's rich system and user administration capabilities and model configuration take the hassle out of deploying and managing Subversion and the tools developers use with it. Learn more about uberSVN and get a free download at: http://p.sf.net/sfu/wandisco-dev2dev _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users