On 9 August 2011 04:44, charles green <xxzzb...@yahoo.com> wrote:
> the exact message is, "Can't issue MDI command when not homed."  AXIS 
> EMC2.4.6 on Ubuntu 8.04.  the homing sequence is axis2=0, axis0=1, axis1=2.  
> axis3 is not included in the home sequence and has no pins assigned to homing 
> switch in the hal ini.  the configuration is a mill xyza millimeter.

That sounds like an error in that particular config. Axis3 should have
a HOME_SEQUENCE but zero HOME_VELOCITY, I think. I will try to
experiment when I get home tonight.

-- 
atp