Andy Pugh wrote: > It should conventionally be "C" (A is parallel to X, B is parallel to > Y, C is parallel to Z) > > You control which axes are enabled with > COORDINATES = XYZA > in the INI file. If you want to start using C then you would need to > edit that to XYZC, but to also add 2 more axes and alter the HAL file > to send axis.5 values to the stepper motor. I think you are probably > better staying with the XYZA configuration (it means all your G-code > continues to work). >
Yes, it should be C, but the problem is that EMC won't run with B or C, only 'A' (unless I've messee up the 'ini' somehow, but I can't see it :-) > If you want to stop changes in A value moving the tool in the preview > display then all you need to do is edit the INI file GEOMETRY setting. > That probably says XYZA. Change that to just XYZ and the A movements > will not be shown. But then the 'A' word doesn't move the chuck either. I would like just to get the display sensible, leaving the mechanism the same. (OK - I don't care if I have to change the 'A' word to 'C' words, I write new code for each project anyway.) I need the machine right now. When I'm finished, I will make a new partition and install the newest version. Maybe there will be some enlightenment? Thanks for your suggestions anyway. Cheers, Robert ------------------------------------------------------------------------------ All the data continuously generated in your IT infrastructure contains a definitive record of customers, application performance, security threats, fraudulent activity and more. Splunk takes this data and makes sense of it. Business sense. IT sense. Common sense. http://p.sf.net/sfu/splunk-d2dcopy1 _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users