Andy Pugh wrote:

> It should conventionally be "C" (A is parallel to X, B is parallel to
> Y, C is parallel to Z)
> 
> You control which axes are enabled with
> COORDINATES = XYZA
> in the INI file. If you want to start using C then you would need to
> edit that to XYZC, but to also add 2 more axes and alter the HAL file
> to send axis.5 values to the stepper motor. I think you are probably
> better staying with the XYZA configuration (it means all your G-code
> continues to work).
> 

Yes, it should be C, but the problem is that EMC won't run with B or C,
only 'A' (unless I've messee up the 'ini' somehow, but I can't see it :-)

> If you want to stop changes in A value moving the tool in the preview
> display then all you need to do is edit the INI file GEOMETRY setting.
> That probably says XYZA. Change that to just XYZ and the A movements
> will not be shown.

But then the 'A' word doesn't move the chuck either. I would like just
to get the display sensible, leaving the mechanism the same. (OK - I
don't care if I have to change the 'A' word to 'C' words, I write new
code for each project anyway.)

I need the machine right now. When I'm finished, I will make a new
partition and install the newest version. Maybe there will be some
enlightenment?

Thanks for your suggestions anyway.

Cheers,

Robert

------------------------------------------------------------------------------
All the data continuously generated in your IT infrastructure contains a
definitive record of customers, application performance, security
threats, fraudulent activity and more. Splunk takes this data and makes
sense of it. Business sense. IT sense. Common sense.
http://p.sf.net/sfu/splunk-d2dcopy1
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to