On Tue, 2012-11-20 at 17:28 -0500, Przemek Klosowski wrote:
... snip
> I can see that, while equalizing the load across the rectifiers, this
> scheme doesn't help with power variation within the 50/60Hz cycle, so some
> derating is still called for, I think.
... snip

I've given this some thought too. I believe the biggest problem, as
Peter mentions, is the current load on the DC bus capacitors while there
is no voltage from the single phase. My thinking has been to have a
separate rectifier and capacitors to get DC, then feed that into the VFD
input, but it's probably cheaper just to buy a larger VFD.

A rotary or static phase converter should help too, but then again, it's
cheaper to buy a bigger VFD than build or buy a converter.

-- 
Kirk Wallace
http://www.wallacecompany.com/machine_shop/
http://www.wallacecompany.com/E45/index.html
California, USA


------------------------------------------------------------------------------