On 4/10/2013 8:56 AM, andy pugh wrote:
> I have bought a Renishaw touch-probe.

I infer you bought only the probe and not the "receiver".

>
> It has an inductive interface to connect to the controller, described
> in patent GB2025073
> It appears that an LC circuit in the probe is shorted out by the probe
> contacts when there is no contact.
> All fairly simple, though finding what the resonant frequency is is
> probably important.

It's been 50 years since I last used a grid-dip meter but it's one way 
to get the job done if you want to know the resonant frequency of a 
tuned circuit.

Regards,
Kent


------------------------------------------------------------------------------