> On Apr 16, 2015, at 8:45 PM, Chris Morley <chrisinnana...@hotmail.com> wrote: > > The 7I85s is a 4 axis stepgen + encoder interface. Does pncconf know how to > make closed loop stepgen + encoder feedback configurations? > > Yes - if you pick an x axis stepper and x axis encoder (but not an x axis > analog) then pncconf will do a closed loop stepper config. > > I haven't check this in a long time so it might need some tweaks. > > Firmware XMLs must be put in /lib/firmware/hm2/BOARDNAME for pncconf > to notice them.
I created a directory /lib/firmware/hm2/5i25 and put the 7i85sx2.xml and 7i85sx2.bit files there. PNCCONF now sees the 5i25 and 7i85s. I also have a 7i84 connected via serial to the 7i85s, that it doesn’t see. Do I also need to add a 7i84.xml file for that to work? Not sure where to find that, it doesn’t seem to be in the config files I downloaded for the 5i25 card. > By 2.8 pncconf will read the info from a live system YAAY! That would be nice! -Tom ------------------------------------------------------------------------------ BPM Camp - Free Virtual Workshop May 6th at 10am PDT/1PM EDT Develop your own process in accordance with the BPMN 2 standard Learn Process modeling best practices with Bonita BPM through live exercises http://www.bonitasoft.com/be-part-of-it/events/bpm-camp-virtual- event?utm_ source=Sourceforge_BPM_Camp_5_6_15&utm_medium=email&utm_campaign=VA_SF _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users