> From: tom-...@bgp.nu
> Date: Sat, 18 Apr 2015 13:32:36 -0400
> To: emc-users@lists.sourceforge.net
> Subject: Re: [Emc-users] Pncconf with 6i25 and 7i85s in 2.7-pre6
> 
> Chris,
> 
> I was mistaken.  There is indeed a 7i84 in the second combo box.  I can 
> select that but then I get the wrong designation for the I/O bits.  That is, 
> I get
> hm2_5i25.0.7i84.0.1.input-00 rather than hm2_5i25.0.7i84.0.0.input-00 (for 
> example).  I assume that is because, as you say, I cannot select the 7i84 on 
> the Connector 3 tab?  Or is it just a bug with the numbering (starting at 1 
> rather than 0)?
> 
> -Tom
> 

Tab 3 has the lowest numbered 7i84, tab 2 would be the next. that's how the 
firmware describes them.

Pncconf only supports mode 1 and 3 ( question on your other email).
If you need something else then you need to hand edit.

Chris M
                                          
------------------------------------------------------------------------------
BPM Camp - Free Virtual Workshop May 6th at 10am PDT/1PM EDT
Develop your own process in accordance with the BPMN 2 standard
Learn Process modeling best practices with Bonita BPM through live exercises
http://www.bonitasoft.com/be-part-of-it/events/bpm-camp-virtual- event?utm_
source=Sourceforge_BPM_Camp_5_6_15&utm_medium=email&utm_campaign=VA_SF
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to