On 5 February 2016 at 22:22, Todd Zuercher <zuerc...@embarqmail.com> wrote:
> It is a gang router (didn't start out as one), and is connected to 9 > different single phase 110v breakers. One for each of the six 15amp routers > plus 3 more for the control, and motion. (that stuff totals at most another > 15amps.) I am not familiar with your local regs. I am not even qualified to wire to my own local regs but: One machine should have one power cord. The upstream breaker should be sized for that power cord (or, conversely, that power cord should match the breaker). If for no other reason than to make it very clear that the machine is off before working on it. Then, internal to the machine, you should have power distribution and thermal/overload trips for each spindle. -- atp If you can't fix it, you don't own it. http://www.ifixit.com/Manifesto ------------------------------------------------------------------------------ Site24x7 APM Insight: Get Deep Visibility into Application Performance APM + Mobile APM + RUM: Monitor 3 App instances at just $35/Month Monitor end-to-end web transactions and take corrective actions now Troubleshoot faster and improve end-user experience. Signup Now! http://pubads.g.doubleclick.net/gampad/clk?id=272487151&iu=/4140 _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users