On 26.03.17 00:01, linden wrote: > Hello All > > Should I ground both ends of the shield for shielded pair? I am not sure > what the best practice is see pdf attached for what I have now in black and > the chunk in red I am not sure about.
Grounding the shield at both ends will create a ground loop, and therefore trouble. If the " JP4 Shell" in the drawing were only the connector shell, not connected to anything, then connecting to it would merely extend the screen right to the end. BUT you've added "Gnd" to the label, to indicate that it's grounded at that end, right? Draw a great looping line connecting the two "Gnd" labels. What do you have if the red connection is made? My preference is to ground screens at the driving end, and you've done that. No more is needed. Erik ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users