Have used the latest origin/master not more than a few weeks old but
have not checked against older version. Will do this sooner or later,
hopefully within a week.
Den 2023-06-26 kl. 07:29, skrev John Dammeyer:
OK.
I'll try that for you.
I'm wondering if perhaps spindle acceleration time or some other HAL
parameter gets flagged with an incorrect error message. I've done power
tapping from .ngc files without issue but I've not used the 'I' parameter.
John
-----Original Message-----
From: Nicklas SB Karlsson [mailto:n...@nksb.eu]
Sent: June 25, 2023 10:09 PM
To: emc-users@lists.sourceforge.net
Subject: Re: [Emc-users] G33.1 error then g-code file parsed
Run from MDI then there is no error message for me either. Put the same
rows in a .ngc file adding M2 and bottom there is an interpreter error
message then loading the file and display not updated. Looking at bottom
the program is however actually loaded and seems to work OK.
Nicklas Karlsson
Den 2023-06-26 kl. 01:26, skrev John Dammeyer:
I ran the following commands from the MDI without issue from AXIS 2.8.1
with
MESA 7i92H controlling an AC Servo motor (step/dir) for the spindle.
G1 X0 Y0 F20
G1 Z0
S200 M3
G33.1 Z-0.7 K0.05 I3.0
M5
Interesting watching the spindle RPM indicator, and you can hear it too of
course.
Goes down to tap the 0.05" pitch (20TPI thread) at 200RPM
Reverses and goes up at 600 RPM.
Without the I3.0 it goes up at 200 RPM.
John
-----Original Message-----
From: Nicklas SB Karlsson [mailto:n...@nksb.eu]
Sent: June 25, 2023 9:07 AM
To: emc-users@lists.sourceforge.net
Subject: Re: [Emc-users] G33.1 error then g-code file parsed
There is positioning move XYZ in real program but happened to remove
them then I should make a small test case.
Adding positioning move to test case make no difference. Linuxcnc report
a file interpretation error and do not update display but program seems
to work supposed to.
Nicklas Karlsson
Den 2023-06-23 kl. 16:20, skrev Chris Radek:
I would add positioning moves (positioning all of XYZ) before the
G33.1 because otherwise the tapped hole can be anywhere - the
program is indeterminate. This sure might mess up any attempt by
your GUI to check the program or generate a preview.
Chris
On Wed, Jun 14, 2023 at 09:14:20PM +0200, Nicklas SB Karlsson wrote:
I put the lines below into a file:
?? M3 S100
?? G33.1 Z-30.474 K0.8 I3.000
?? M5
?? M2
Then I read into Linuxcnc I get error message:
?? parse_file interp_error
Removing the line with G33.1 then no error message so it is something
with this row. Program do however execute as expected with G33.1 line
even though there is an error message so no real problem. Also execute
without an error message if run manually in MDI mode. Use origin/master
last commit Mon May 8 16:10:03 2023 +0200
404aa407f136ce91a3e6bf911c7bda54011a74e9 Anybody else had similar
problem?
Nicklas Karlsson
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users