Two things do jump out as slightly odd in this script. Not that they will make
any difference to the result.

On Jan 22, 2008 4:43 PM, asreeve <[EMAIL PROTECTED]> wrote:

> discharge=dot(head.getFaceGrad(),kond.getHarmonicFaceValue())

kond.getHarmonicFaceValue() is a scalar and head.getFaceGrad() is a vector.
Does it make any sense to dot them? Do you not just mean multiply?

> transportEq2=(TransientTerm()==
>                -PowerLawConvectionTerm(coeff=vel())
>                -DiffusionTerm(coeff=Disp))

I think that vel() evaluates the variable and returns a numpy array.
This means that
the coefficient will not be updated if kond or head change. I realize
that vel never changes
in this calculation.

Cheers

-- 
Daniel Wheeler