On Feb 27, 2006, at 1:19 PM, Ed Maste wrote:
On Mon, Feb 27, 2006 at 11:07:35AM -0500, Vivek Khera wrote:
I get a 9600 baud console with the following after upgrade from 5.4:
This is what I'm planning on putting in UPDATING:
The i386 loader(8) now defaults to the serial speed set by the
previous boot stage, if the comconsole is already in use. If
you've changed BOOT_COMCONSOLE_SPEED in make.conf(5) and
installed a new loader, but have not rebuilt and
reinstalled the
boot blocks, then your loader will leave the console at 9600
baud. You may either set comconsole_speed in loader.conf
(5), or
reinstall new boot blocks as described in boot(8).
-ed
... or set -S option in boot.config.
From other discussion, the -S option seems to be the most
straightforward method.
The boot block update is described in boot0cfg(8) not boot(8), and
must be done post-installworld, just to be 100% clear.
Thanks for adding it to UPDATING.
_______________________________________________
freebsd-stable@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-stable
To unsubscribe, send any mail to "[EMAIL PROTECTED]"