Hello, our lab has been using freesurfer for years, dating back to version 4.3 
and recently ran into a problem with a new installation of 7.2.  After adding 
control points in the typical fashion and saving them into the subject’s tmp 
folder as “control.dat” and running -autorecon2-cp, mri_normalize seems to 
correctly identify the control points, the correct number, the mean value and 
the scaling. The subsequent steps complete without failure and brain.mgz is 
generated with 110 values in the cp spots. However, the subsequent wm.mgz and 
brainmask.mgz images do not seem to have been affected by the control points 
(e.g. the control point locations aren’t at a 110 value and the white matter is 
almost identical). Curious if anyone else has run into the issue? Is there a 
new workflow in this version of Freesurfer that I’m neglecting?

So far I have tried to create a new control.dat using freeview and copied the 
old points into that file, and run twice with the same results.