On 04/08/10 11:07, Mark Zelden wrote:
Skip has talked about this in the past and in SHARE sessions.

What we have done for years is use a different "newly formatted"  sysplex
couple and CFRM couple data sets that we IPL with during DR.  This has
also been discussed.

Regards,

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS
mailto:mzel...@flash.net
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html
Systems Programming expert at http://expertanswercenter.techtarget.com/


That's what we do at DR also. I was wondering if the first IPL with the incorrect CFRM policy 'corrupted' the sysplex couple dataset in such a way that it didn't re-read the CFRM couple dataset for the policy which was rewritten with the correct CPU serial number.

Mark Jacobs


On Thu, 8 Apr 2010 09:39:36 -0500, Field, Alan C.
<alan.c.fi...@supervalu.com>  wrote:

Mark, I don't know but we used to run into the same problem at DR until
we started defining our CFRM policy with 4 CFs.

CF1 and CF2 are the ones at home. CF3 and CF4 are the ones at DR.

I define the policies with a preflist of (CF1,CF2,CF3,CF4).

Now when we're at home or DR IPL proceeds without a hitch.

I think I got the idea for doing this from a post on this list a few
years ago.

Alan

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On
Behalf Of Mark Jacobs
Sent: Thursday, April 08, 2010 09:31
To: IBM-MAIN@bama.ua.edu
Subject: SYSPLEX/CFRM Couple dataset(s) relationship

At our last DR exercise we had an incorrect CPU serial number in our
CFRM policy which resulted in a failure in our IPL. We fixed the CFRM
policy and re-wrote it replacing the incorrect policy (same policy
name).

When we re-ipled, the system was still looking for the CF lpar with the
incorrect CPU serial number even though the CFRM policy with the old
serial number wasn't in the CFRM dataset. We couldn't get the system to
IPL until I deleted and redefined the SYSPLEX couple dataset.

Does the sysplex couple dataset retain information about the CFRM policy

in use other than the name of the last used CFRM policy?

--
Mark Jacobs
Time Customer Service
Tampa, FL
----

It is impossible to make anything foolproof, because fools
are so ingenious.

  -- Robert Heinlein

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html



--
Mark Jacobs
Time Customer Service
Tampa, FL
----

It is impossible to make anything foolproof, because fools
are so ingenious.

 -- Robert Heinlein

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to