If you are new to peer mode this is a good white paper on the subject http://www-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/WP100265. Though there appears to be a newer one which I have not read-WP100820.
Otherwise to strictly answer your question on how to define the links the HCD piece is fairly automatic. Define your TYPE=CFP CHPIDs on the respective processors. Select one of the CHPIDs with "F" then "P." Specify the destination CHPID information then accept or change the suggested control units and devices. Repeat for redundant links. Regards, Kevin -----Original Message----- From: IBM Mainframe Discussion List [mailto:ibm-m...@bama.ua.edu] On Behalf Of ibmnew Sent: Friday, April 09, 2010 6:54 PM To: IBM-MAIN@bama.ua.edu Subject: How to define couple links using HCD Hi all We want to replace out sysplex time with STP. We purchased two CFs(Z10) and installed two couple links with ICB-4 between the CFs. Could you help us to define the couple links using HCD for it. Thanks a lot! Best Regards, Jason Cai ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html