We have done quite a lot of DR testing in the last year and a half. We
defined all coupling facilities in our active CFRM policy, the same way Alan
C. Field described, and never had a problem IPLing our sysplex. The only
difference is that we start JES2 with RECONFIG parameter, to set the CKPT1
(allocated in a coupling facility) to INUSE=NO, so that the CKPT2 will be used.

Never had any problems going back either.

With applications it is not so easy, but starting a sysplex is just a routine.

The tests were done with z/OS 1.9 and 1.10.

-- 
Zaromil

----------------------------------------------------------------------