On Tue, 20 Jul 2010 06:54:35 -0700, Charles Mills <charl...@mcn.org> wrote:
>
>If an exit is defined, you can assign a routine to it dynamically. The
>question is if an exit is not defined, can you define it dynamically? My
>reading is no, but I would love to be wrong.
>

Yes, via SMFPRMxx update and a SET SMF=xx command.  

Where  / what exactly are you reading and where?

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS       
mailto:mzel...@flash.net                                          
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html 
Systems Programming expert at http://expertanswercenter.techtarget.com/

----------------------------------------------------------------------