On Tue, 20 Jul 2010 06:54:35 -0700, Charles Mills <charl...@mcn.org> wrote: > >If an exit is defined, you can assign a routine to it dynamically. The >question is if an exit is not defined, can you define it dynamically? My >reading is no, but I would love to be wrong. >
Yes, via SMFPRMxx update and a SET SMF=xx command. Where / what exactly are you reading and where? Mark -- Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS mailto:mzel...@flash.net Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html Systems Programming expert at http://expertanswercenter.techtarget.com/ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html