On Fri, 11 Nov 2005 17:22:47 +0200, Ali Serdar Yakut <[EMAIL PROTECTED]> wrote:
>No paths physically available message is given when I try to online >unconditionally. > 3745 is connected through parallel cable - optica - escon channel. > When I check the MOSS conssole there are parameters to be set - >Adapter Type: CADS/BCCA >NSC or ESC address >Channel Burst Length >Data Transfer Mode > Most probably these parameters are causing the problem now... >Anybody has any ide for IODF, and 3745 Channel Adapter parameters for such a >connection? Serdar - here is my CU and LU definitions - ours is a parallel connection also: Logical Control Unit / Device List Row 1 of 1 Command ===> _________________________________________ Scroll ===> CSR Processor ID . . : MAEY36 ENTER to continue. -------Device------- --------Attached Control Units--------- Number Type 1--- 2--- 3--- 4--- 5--- 6--- 7--- 8--- UA 0980 3745 0980 80 **************************** Bottom of data ***************************** View Device / Processor Definition Row 1 of 1 Command ===> _____________________________________ Scroll ===> CSR Select one or more processors to view the device candidate list, or ENTER to continue without selection. Device number . : 0980 Device type . : 3745 Preferred Explicit Device / Processor ID UA Time-Out STADET CHPID Candidate List # MAEY36 80 Yes No No Hope this helps. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html