I'm not sure if the past few posts are in response to my comment about a 
crippling COBOL/MVCL problem. If so--and it was not my dog, as Schmuel 
would say--the offending application had previously worked OK on earlier z 
hardware. Moving from z10 to z196 was a day-one disaster. Once the smoking 
MVCL was implicated, the application was improved dramatically with a 
minor rewrite of just a few lines of source code. 

The z196 problem resulted from excessive MVCL execution in the compiled 
code. MCL was eventually updated in some way to avoid the problem. 
'Reasonable' use of MVCL would not have caused a crisis in the first 
place. The application induced the problem, which did not raise any alarm 
on earlier hardware. 

.
.
JO.Skip Robinson
SCE Infrastructure Technology Services
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
jo.skip.robin...@sce.com



From:   "Farley, Peter x23353" <peter.far...@broadridge.com>
To:     IBM-MAIN@bama.ua.edu
Date:   07/15/2011 07:51 AM
Subject:        Re: Z196 Cobol pgm with higher CPU
Sent by:        IBM Mainframe Discussion List <IBM-MAIN@bama.ua.edu>



May I surmise from the initials MCL that this is a micro- or milli-code 
fix for a z196 machine?  Is it possible that such a fix has implications 
on lower architecture boxes like z10's?  I have no access to IBMLINK or 
RETAIN or I would look these things up myself.

The reason I ask such a question is that in several application-oriented 
CPU reduction efforts in recent years involving COBOL code, I found that 
some quite large reductions in average CPU time were gained from the 
elimination or at least from the minimization of MVCL and CLCL 
instructions in the generated code.

If the z196 has a "speedup" fix for these instructions and if that fix 
could be back-ported to z10's or even to lower-order boxes, a possibly 
large amount of COBOL application CPU time could be saved over the z 
universe...

Peter

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On
> Behalf Of Vernooij, CP - SPLXM
> Sent: Friday, July 15, 2011 8:45 AM
> To: IBM-MAIN@bama.ua.edu
> Subject: Re: Z196 Cobol pgm with higher CPU
> 
> I just had it checked and it is MCL 089, available in februari.
> RETAIN info: MCL fix U799O089 EC N29799 B28B.
> Desc: performance issue seen on customer applications which heavily use
> the move char long, move char long extended and move char long Unicode
> instructions.



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html