> -----Original Message-----
> From: IBM Mainframe Discussion List 
> [mailto:[EMAIL PROTECTED] On Behalf Of Chase, John
> Sent: Tuesday, February 05, 2008 11:15 AM
> To: IBM-MAIN@BAMA.UA.EDU
> Subject: Re: Technical questions about CICS STARTBR and ENDBR
> 

[snip]

> For completeness, it should be noted that FILE() can also be specified
> on ENDBR, so that multiple files can be browsed concurrently 
> within the
> same transaction.
> 
>     -jc-

To be a bit more exact, FILE() is a __required__ parameter on both the
STARTBR and the ENDBR. Well, maybe the EIB field can be filled in
separate from the EXEC CICS statement itself. I don't know if the
translator allows that or not. REQID is optional and defaults to 0 if
not specified.

--
John McKown
Senior Systems Programmer
HealthMarkets
Keeping the Promise of Affordable Coverage
Administrative Services Group
Information Technology