Jerry, Change device type to UNIT=3270,MODEL=X to allow for all models of 3270 terminals. Dennis
-----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Jerry Fuchs Sent: Wednesday, November 19, 2008 9:56 AM To: IBM-MAIN@BAMA.UA.EDU Subject: IOGEN of 2074 I am trying to gen two 2074 controllers using the example in the planning and installation guide as follows CU0700 CNTLUNIT CUNUMBR=0700,PATH=(04),UNITADD=((00,016)),SHARED=N, * PROTOCL=D,UNIT=3174 DEV700 IODEVICE ADDRESS=(700,016),CUNUMBR=(0700), * UNIT=3277 * CU0800 CNTLUNIT CUNUMBR=0800,PATH=(25),UNITADD=((00,016)),SHARED=N, * PROTOCL=D,UNIT=3174 DEV800 IODEVICE ADDRESS=(800,016),CUNUMBR=(0800), * UNIT=3277 When I execute //MIGRIOCP EXEC PGM=CBDMGHCP, // PARM='MIGR,I,WENDYS,2066-003,LPAR' I get messages E CBDA297I Control unit 0700 of type 3174 cannot attach device 0700 of type 3277-2. E CBDA297I Control unit 0800 of type 3174 cannot attach device 0800 of type 3277-2. What am I doing wrong? We are on z/OS 1.7 Jerry ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html