On Tue, 16 Dec 2008 09:23:53 -0600, Paul Gilmartin wrote:

>On Tue, 16 Dec 2008 08:02:57 -0600, Tom Marchant wrote:
>
>>On Mon, 15 Dec 2008 18:33:36 -0600, Paul Gilmartin wrote:
>>
>>>I shudder whenever I read in the PoOp that bit 31 of
>>>the TOD clock toggles once per megamicrosecond (sic, IIRC).
>>
>>Ummm.....
>>I think it has always said that bit 51 increments every microsecond.  It
>>says that bit 31 increments every 1.048576 second.
>>
>OK.  Not in the PoOp, but certainly in the diagram on p. 3 of
>
>    International Technical Support Organization
>    Server Time Protocol Planning Guide
>    December 2006
>    SG24-7280-00
>
>    http://www.redbooks.ibm.com/redbooks/pdfs/sg247280.pdf

ARRRGH!!!

"This interval is sometimes called a mega-microsecond."

oh, really?  By whom?

-- 
Tom Marchant

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to