O'Brien, David W. [C] , NIH/CIT wrote:
Why not use HSM ABAR Backups which include migrated datasets?

Try figuring out how to recall a single dataset from an ABARS backup and it becomes clear ABARS is really designed with recovery in mind, not with providing easy access to archives of specific datasets.
  JC Ewing

Dave O'Brien
NIH Contractor
________________________________________
From: IBM Mainframe Discussion List [ibm-m...@bama.ua.edu] On Behalf Of Mark 
Jacobs [mark.jac...@custserv.com]
Sent: Tuesday, May 12, 2009 11:37 AM
To: IBM-MAIN@bama.ua.edu
Subject: Re: ADRDSSU protection [was:RE: Using FTP to send loadlib]

R.S. wrote:
Roach, Dennis (N-GHG) pisze:
As a sysprog, I agree.
For the applprog, verify what happens when a data set is on ML1 or ML2
and a masked include is used. DSS used to skip these and still have a
zero return code. This caused the application source to be left off of
their DR tapes.
This is well-know and documented behavior. We shouldn't assume, that
applprog is less intelligent than sysprog.
And this "gotcha" is no justification to for denying ADRDSSU at all.
Applprogs (everyone) can make mistake without ADRDSSU as well.
Applprogs are probably  allowed to use many tools which they don't
know well.


Jobstep 1 - HRECALL with wait option
Jobstep 2 - DFDSS processing.

It's not rocket science.

A simpler and more fool-proof method:
Instead of a separate step, hang an unreferenced DD statement on the actual DFDSS step for all datasets that "must" be dumped and which have any possibility of being migrated. Step allocation will cause all DD-referenced datasets to be recalled before step execution proceeds, and there is no possibility of migration occurring before the dump (which could happen if a separate recall step occurs just before DFHSM interval migration, since the dataset is not opened to reset the last-referenced date). If a dataset is migrated because it has not been referenced as recently as the others in the backup step, it might also make sense to question if it is appropriate for that dataset to be in the same backup collection.
  JC Ewing

--
Mark Jacobs
Time Customer Service
Tampa, FL
----

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to