Do you have any kind of automation package available to you? On Thu, Mar 16, 2023 at 8:11 AM Richard McIntosh < richard.mcint...@oracle.com> wrote:
> Is there anyway to get alerted to a linklist error duing the IPL process. > The error messages come out to early for any MPF processing to hilite it > and they rolled by to quick for operations to notice and caused TLMS to not > get initialized. Dataset is not in master catalog and the wrong volser was > specified. > > > IGGN307I SYSP01,SYSR.TLMS.R14MA.CTAPLINK,DATA SET NOT FOUND ON > VOLUME > > IEA716I UNABLE TO OPEN LIBRARY - LNKLST DATA SET IGNORED > > SYSR.TLMS.R14MA.CTAPLINK > > > > I googled an old (18 years ago) message about someone using the IEAVMXIT > exit to check some storage to see if any error flags were set, but there > was no mention of what storage it was. > > > > Thanks > > > > Richard McIntosh > > > > > > > > > > > > > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN