On Fri, 22 Sep 2023 20:59:11 +0000, Schmitt, Michael wrote:

>Thanks, I overlooked the "interacting with JES topic".
>
>Looks like you can GET (receive) sysout but not PUT.
>
>I suppose a worst case solution would be to wrap the output in JCL, where the 
>JCL executes code to build LRECL=133 lines from instream data and then copy 
>that to SYSOUT.
>  
FTP limits JESLRECL to 254 which may be sufficient to avoid the "JCL executes 
code to build."

(I assume IEBGENER step with instream SYSUT1.)

254!?  Antique JES3 limit.  Both JES2 and JES3 allow far more nowadays.
Time for an RFE^H^H^HIdea?

-- 
gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN