Hello,

I see another developer on here.  And we send our product out using TSO XMIT.  
Which gives rise to a question.  I saw some techie state that he would not 
install a product unless he could use SMP/E.  Is this something us developers 
should explore or is it a big headache that is not worth it?

Thanks, 

Duffy Nightingale
Sound Software Printing, Inc.
www.soundsoftware.us
du...@soundsoftware.us
Phone: 360.385.3456
Fax: 973.201.8921
 
The information in this e-mail, and any attachment therein
is confidential and for use by the addressee only. If you are
not the intended recipient, please return the e-mail to the
sender and delete it from your computer. Although Sound
Software Printing, Inc. attempts to sweep e-mail and
attachments for viruses, it does not guarantee that either
are virus-free and accepts no liability for any damage
sustained as a result of viruses.


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of R.S.
Sent: Monday, July 22, 2013 10:18 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: BLKSIZE=3120

W dniu 2013-07-22 18:08, Ed Jaffe pisze:
> A customer (mildly) complained thatsome of our product allocations 
> still use BLKSIZE=3120. I vaguely remember trying to change all of 
> them to BLKSIZE=0 many years ago (probably before OS/390) and running 
> into some issues with certain IBM utilities. Unfortunately, I can't 
> remember the specifics.
>
> In starting to revisit this again, I noticed numerousoccurrences of 
> '3120' in IBM help and documentation. For example, the TSO/E RECEIVE 
> command HELP claims that the log data set must be BLKSIZE=3120:
>
> <TSO/E RECEIVE command HELP>
> LOGDATASET       You may specify an alternate data set to be
>                  used for the logging of the transmitted data.
>                  This data set will be created if it does not
>                  exist.  The data set should be created with
>                  a logical record length of 255, a record format
>                  of VB and a blocksize of 3120.
> ...
>
> LOGDSNAME        You may specify an alternate data set to be
>                  used for the logging of the transmitted data.
>                  This data set will be created if it does not
>                  exist.  The data set should be created with
>                  a logical record length of 255, a record format
>                  of VB and a blocksize of 3120.
> </TSO/E RECEIVE command HELP>
>
> Is this just outdated help? Or does this restriction still exist?
>
> is z/OS still a "mine field" filled with subtle dependencies on 
> BLKSIZE=3120?
>
Well, IMHO it's not restriction, it is just allocation default. Good default in 
very old days, but not very bad today.
Note, The difference between ~3k and optimal ~27k seem to be large, but the 
effects (performance, space used) give no big difference.
BTW: DB2, LOGGER, MQ, and many many VSAM exploiters do use blocks 4kB. 
Is it far from 3kB?
Of course you can try the above datasets with other (SDB) blocksize, and I bet 
nothing will break. Why didn't they change it? Well, it time to re-start the 
following subthreads:
- TSO is moribound
- if it isn't broken don't fix it (see latest implementation as IMBED for 
catalogs).


Regards

--
Radoslaw Skorupka
Lodz, Poland






--
Tre tej wiadomoci moe zawiera informacje prawnie chronione Banku 
przeznaczone wycznie do uytku subowego adresata. Odbiorc moe by jedynie 
jej adresat z wyczeniem dostpu osób trzecich. Jeeli nie jeste adresatem 
niniejszej wiadomoci lub pracownikiem upowanionym do jej przekazania 
adresatowi, informujemy, e jej rozpowszechnianie, kopiowanie, rozprowadzanie 
lub inne dziaanie o podobnym charakterze jest prawnie zabronione i moe by 
karalne. Jeeli otrzymae t wiadomo omykowo, prosimy niezwocznie 
zawiadomi nadawc wysyajc odpowied oraz trwale usun t wiadomo 
wczajc w to wszelkie jej kopie wydrukowane lub zapisane na dysku.

This e-mail may contain legally privileged information of the Bank and is 
intended solely for business use of the addressee. This e-mail may only be 
received by the addressee and may not be disclosed to any third parties. If you 
are not the intended addressee of this e-mail or the employee authorised to 
forward it to the addressee, be advised that any dissemination, copying, 
distribution or any other similar activity is legally prohibited and may be 
punishable. If you received this e-mail by mistake please advise the sender 
immediately by using the reply facility in your e-mail software and delete 
permanently this e-mail including any copies of it either printed or saved to 
hard drive. 

BRE Bank SA, 00-950 Warszawa, ul. Senatorska 18, tel. +48 (22) 829 00 00, fax 
+48 (22) 829 00 33, www.brebank.pl, e-mail: i...@brebank.pl
Sd Rejonowy dla m. st. Warszawy XII Wydzia Gospodarczy Krajowego Rejestru 
Sdowego, nr rejestru przedsibiorców KRS 0000025237, NIP: 526-021-50-88. 
Wedug stanu na dzie 01.01.2013 r. kapita zakadowy BRE Banku SA (w caoci 
wpacony) wynosi 168.555.904 zotych.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to