Listers: We are doing a VSE to z/OS conversion and had to do the following since we have no source.
We punched out a CIL phase from a VSE system. We put the phase in a z/os pds member (lrecl 80) and it looked like this: Phase modname ESD TXT RLD END /* We edited the phase so that it looked like this: ESD TXT RLD END We then tried to linkedit the phase with IEWL and got the following messages: z/OS V1 R13 BINDER 15:51:52 FRIDAY AUGUST 9, 2013 BATCH EMULATOR JOB(LINKEDT2) STEP(LKED ) PGM= IEWL IEW2278I B352 INVOCATION PARAMETERS - XREF,LIST IEW2359E 240B SECTION FA010 CONTAINS AN RLD WITH AN INVALID ADCON LOCATION. CLASS = B_TEXT, ELEMENT OFFSET = FFAFFF88 IEW2307E 1113 CURRENT INPUT MODULE NOT INCLUDED BECAUSE OF INVALID DATA. IEW2322I 1220 3 NAME HA010(R) IEW2230S 0414 MODULE HAS NO TEXT. IEW2648E 5111 ENTRY RR$$AA IS NOT A CSECT OR AN EXTERNAL NAME IN THE MODULE. IEW2677S 5130 A VALID ENTRY POINT COULD NOT BE DETERMINED. IEW2008I 0F03 PROCESSING COMPLETED. RETURN CODE = 12. Any ideas? Thank you, Roberto ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN