The exact same thread is going on over on the VSE list. Pretty much the same answers too!
Chuck Arney Arney Computer Systems On Aug 9, 2013, at 3:13 PM, Roberto Halais <roberto.hal...@gmail.com> wrote: > Listers: > > We are doing a VSE to z/OS conversion and had to do the following since we > have no source. > > We punched out a CIL phase from a VSE system. > > We put the phase in a z/os pds member (lrecl 80) and it looked like this: > > Phase modname > ESD > TXT > RLD > END > /* > > We edited the phase so that it looked like this: > > ESD > TXT > RLD > END > > We then tried to linkedit the phase with IEWL and got the following > messages: > > z/OS V1 R13 BINDER 15:51:52 FRIDAY AUGUST 9, 2013 > > BATCH EMULATOR JOB(LINKEDT2) STEP(LKED ) PGM= IEWL > > IEW2278I B352 INVOCATION PARAMETERS - XREF,LIST > > > IEW2359E 240B SECTION FA010 CONTAINS AN RLD WITH AN INVALID ADCON LOCATION. > CLASS = B_TEXT, ELEMENT OFFSET = FFAFFF88 > IEW2307E 1113 CURRENT INPUT MODULE NOT INCLUDED BECAUSE OF INVALID DATA. > > > > IEW2322I 1220 3 NAME HA010(R) > > IEW2230S 0414 MODULE HAS NO TEXT. > > IEW2648E 5111 ENTRY RR$$AA IS NOT A CSECT OR AN EXTERNAL NAME IN THE > MODULE. > IEW2677S 5130 A VALID ENTRY POINT COULD NOT BE DETERMINED. > > IEW2008I 0F03 PROCESSING COMPLETED. RETURN CODE = 12. > > > > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN